Digital Input to Output Link

Digital Input to Output Link

This action is a true I/O Bridge. It connects the input of a channel to the output of the same channel, another channel on the same web gateway, or another channel on another web gateway. You can flip a switch and activate a light in remote location.

Digital Output Control

Select “Digital Output Control” action to allow for a link between the digital input state to the digital output state. You can control an output with an input on the same channel, same web gateway, or on a different web gateway.

X10 Control

The X10 Control action allows you to create a virtual light switch by linking a digital input to an X10 command. You need an X10 smart board and controller. Remember to set the channel mode to X10 if you are going to use this action. The X10 Control action can control an X10 outlet with the state of a digital input on the same web gateway or on a different web gateway.

Servo Position Control

You can set the position of a servo depending on the state of a digital input. The positions correspond to fixed positions on a servo when the input is high or low. Flip the input and you get the reverse set position. This action works with the Servo smart board installed on the same web gateway or on a different web gateway.